A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php5/sessions/ci_session9e07d44f51b309a195260d5cee57fb0b9ec914c3): failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 156

Backtrace:

File: /var/www/tradedeals.biz/cdi/application/libraries/Ion_auth.php
Line: 67
Function: library

File: /var/www/tradedeals.biz/cdi/application/controllers/Product.php
Line: 6
Function: __construct

File: /var/www/tradedeals.biz/index.php
Line: 292
Function: require_once

Endoscopy Disposable 3/4/5 Grasping Forceps - Zhuji Peng Tian Medical Instrument Co., Ltd

Endoscopy Disposable 3/4/5 Grasping Forceps

PRICE: contract price
Product Description
Disposable Grasping forceps Basic Info Model: PTG-2323-Z5 Certification: CE, CMDCAS, ISO13485 Quality Guarantee Period: Two Years Logo Printing: OEM, Customization Trademark: T-VICMED HS Code: 9018909010 Type: Endoscopic Accessories Sterilization:Ethylene Oxide Sterilization Group: Adult or Pediatric Package Material: PE+Tyvek(1059b), Corrugated Carton Package: 1PC/Bag Origin: Zhuji, Zhejiang, China MOQ: 50PCS Leading time: 15-20 Days Product description  Usage: It is used to grasp and remove foreign body from alimentary tract in human body in the combined use of endoscope. Features: Disposable, no need to re-sterilize, avoiding cross contamination, convenient to use and reducing the clinical workload. The jaw is made up of medical-use stainless steel which has good biocompatibility. The head end is smooth through elaborately grinding, without damage to endoscope. The head is precisely designed for grasping foreign body accurately and firmly. Material Table                      Component           Material          Standard                          Jaws X5CrNiCuNb16-4X5CrNi18-10 EN10088-1-2005               Prongs, Net, Loop X5CrNi18-10 EN10088-1-2005 Sheath of jaw-shaped grasping forceps X5CrNi18-10 EN10088-1-2005 Sheath of prong-shaped, net-shaped and combined grasping forceps PTFE, PE ISO13000-2005ISO1872-1-1993                    Pulling wire X5CrNi18-10, NiTi EN10088-1-2005ASTM F2063-2012                      Handle ABS ISO2580-1-2002                 Silicon rubber Silicone Rubber ISO23529-2010                         Net Nylon ISO1874-2010                     Coating PE ISO1872-1-1993 Specification Model O.D.(mm) Working Length(mm) Endoscope Channel(mm) PTG-2316-Z3 2.3 1600 2.8 PTG-2323-Z3 2.3 2300 2.8 PTG-2316-Z4 2.3 1600 2.8 PTG-2323-Z4 2.3 2300 2.8 PTG-2316-Z5 2.3 1600 2.8 PTG-2323-Z5 2.3 2300 2.8


Other products

Company Info

Zhuji Peng Tian Medical Instrument Co., Ltd
Contact Person:
Xiongwei He
Phone:
86-0575-87128773

0.0137:0.95MB

A PHP Error was encountered

Severity: Warning

Message: rewind() expects parameter 1 to be resource, boolean given

Filename: drivers/Session_files_driver.php

Line Number: 188

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: filesize(): stat failed for /var/lib/php5/sessions/ci_session9e07d44f51b309a195260d5cee57fb0b9ec914c3

Filename: drivers/Session_files_driver.php

Line Number: 192

Backtrace: