A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php5/sessions/ci_session25b77bdc991c0a4af4dbce6f9fb4adeb2bbaf0fe): failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 156

Backtrace:

File: /var/www/tradedeals.biz/cdi/application/libraries/Ion_auth.php
Line: 67
Function: library

File: /var/www/tradedeals.biz/cdi/application/controllers/Product.php
Line: 6
Function: __construct

File: /var/www/tradedeals.biz/index.php
Line: 292
Function: require_once

Lsg-1800b High Precision Rotation Luminaire Goniophotometer Measured Data Meets Ies Standard Format - Lisun Electronics Inc

Lsg-1800b High Precision Rotation Luminaire Goniophotometer Measured Data Meets Ies Standard Format

PRICE: 23800 USD
Product Description

LSG-1800B/LSG-1700B/LSG-1600B Rotation Luminaire Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B is an update version for LSG-1800, the LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on. 


Specification:

• Meets the requirements of CIE, IEC, IES LM-79 & GB standards

• Reaching many measurement ways such as B-β and C-γ

• The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates around itself with an angle of (C)±180°(or 0-360°)

• Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~107cd(detector)

• The accuracy of angle: 0.0017° (LSG-1800B) and 0.01° (LSG-1700B/LSG-1600B)

• Accuracy of photometry: CIE Class A (Class L is for option)

• Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%

• English version software can run in WinXP, Win7 or Win8

• This system can export data files as following formats(.ies .ldt .cib .tm4 .cie .cen .csv), this kind of format files can be transferred by other illumination and luminaire design software such as DiaLux.

 

Max Size for The Testing Lamp

Dimensions

Weight

Non-Flood Light (Diameter*Depth)

Flood Light (L*W)

LSG-1X00B

Designed according to request

50Kg

LSG-1800B

Φ 1600*580mm

700*600mm

50Kg

LSG-1700B

Φ 1600*550mm

700*600mm

30Kg

LSG-1600B

Φ 1300*400mm

400*400mm

20Kg


Other products

Company Info

Lisun Electronics Inc
Contact Person:
James Peng
Phone:
+8618917996096

0.0240:0.95MB

A PHP Error was encountered

Severity: Warning

Message: rewind() expects parameter 1 to be resource, boolean given

Filename: drivers/Session_files_driver.php

Line Number: 188

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: filesize(): stat failed for /var/lib/php5/sessions/ci_session25b77bdc991c0a4af4dbce6f9fb4adeb2bbaf0fe

Filename: drivers/Session_files_driver.php

Line Number: 192

Backtrace: